Chimney flue measurement to meet code

chimney flue measurement to meet code

These chimney height measurements are important to meet building requirements. Positing a chimney on the home relative to the rest of the home may cause it. fireplaces and their chimneys shall be constructed of concrete or solid . The minimum required bearing length on each end of the fire- place opening shall the actual mandatory requirements of the code, see the indicated section of text. a. fireplaces and their chimneys shall be constructed of concrete or solid masonry . minimum required bearing length on each end of the fireplace opening shall datory requirements of the code, see the indicated section of text. a. The letters.

chimney flue measurement to meet code

The lining material shall be appropriate for the type of appliance connected, according to the terms of the appliance listing and manufacturer's instructions. Flue lining systems shall comply with one of the following: Listed and labeled chimney lining systems complying with UL Factory-built chimneys or chimney units listed for installation within masonry chimneys.

Flue linings other than these covered in Section R Flue lining systems for gas appliances shall be in accordance with Chapter Flue lining and vent systems for use in masonry chimneys with pellet fuel-burning appliances shall be limited to the following: Flue lining systems complying with Section R Pellet vents listed for installation within masonry chimneys.

Flue lining and vent systems for use in masonry chimneys with oil-fired appliances approved for use with Type L vent shall be limited to the following: Listed chimney liners complying with UL When a flue is relined with a material not complying with Section R The label shall include the following message or equivalent language: Clay flue liners shall be installed in accordance with ASTM C and extend from a point not less than 8 inches mm below the lowest inlet or, in the case of fireplaces, from the top of the smoke chamber to a point above the enclosing walls.

The lining shall be carried up vertically, with a maximum slope no greater than 30 degrees 0.

CHAPTER 10 CHIMNEYS AND FIREPLACES | International Residential Code | ICC premiumACCESS

Clay flue liners shall be laid in medium-duty water insoluble refractory mortar conforming to ASTM C with tight mortar joints left smooth on the inside and installed to maintain an air space or insulation not to exceed the thickness of the flue liner separating the flue liners from the interior face of the chimney masonry walls.

Flue liners shall be supported on all sides. Only enough mortar shall be placed to make the joint and hold the liners in position. Listed materials used as flue linings shall be installed in accordance with the terms of their listings and manufacturer's instructions.

2012 International Residential Code

The space surrounding a chimney lining system or vent installed within a masonry chimney shall not be used to vent any other appliance. This shall not prevent the installation of a separate flue lining in accordance with the manufacturer's installation instructions. When two or more flues are located in the same chimney, masonry wythes shall be built between adjacent flue linings.

The masonry wythes shall be at least 4 inches mm thick and bonded into the walls of the chimney. Footings for masonry fireplaces and their chimneys shall be constructed of concrete or solid masonry not less than 12 inches mm thick and shall extend not less than 6 inches mm beyond the face of the fireplace or foundation wall on all sides.

Footings shall be founded on natural, undisturbed earth or engineered fill below frost depth. In areas not subjected to freezing, footings shall be not less than 12 inches mm below finished grade.

How to Install a New Chimney Liner Yourself

Cleanout openings located within foundation walls below fireboxes, when provided, shall be equipped with ferrous metal or masonry doors and frames constructed to remain tightly closed except when in use.

Cleanouts shall be accessible and located so that ash removal will not create a hazard to combustible materials.

chimney flue measurement to meet code

Reinforcing shall conform to the requirements set forth in Table R For chimneys up to 40 inches mm wide, four No. Grout shall be prevented from bonding with the flue liner so that the flue liner is free to move with thermal expansion.

For chimneys more than 40 inches mm wide, two additional No. Two such ties shall be installed at each bend in the vertical bars. Masonry or concrete chimneys in Seismic Design Category D0, D1 or D2 shall be anchored at each floor, ceiling or roof line more than 6 feet mm above grade, except where constructed completely within the exterior walls.

Anchorage shall conform to the requirements of Section R Straps shall be hooked around the outer bars and extend 6 inches mm beyond the bend. Masonry fireboxes shall be constructed of solid masonry units, hollow masonry units grouted solid, stone or concrete.

Where a lining of firebrick not less than 2 inches 51 mm thick or other approved lining is provided, the minimum thickness of back and sidewalls shall each be 8 inches mm of solid masonry, including the lining.

chimney flue measurement to meet code

Where a lining is not provided, the total minimum thickness of back and side walls shall be 10 inches mm of solid masonry. Means shall be provided for access to the flue for inspection and cleaning. An appliance shall not be connected to a flue serving a factory-built fireplace unless the appliance is specifically listed for such installation. A connector shall extend from the appliance to the flue serving a masonry fireplace such that the flue gases are exhausted directly into the flue.

chimney flue measurement to meet code

The connector shall be provided with access or shall be removable for inspection and cleaning of both the connector and the flue. Listed direct connection devices shall be installed in accordance with their listing. A solid fuel-burning appliance or fireplace shall not connect to a chimney passageway venting another appliance.

CHAPTER 8 CHIMNEYS AND VENTS | International Mechanical Code | ICC premiumACCESS

Connectors shall connect to a chimney flue at a point not less than 12 inches mm above the lowest portion of the interior of the chimney flue. Masonry chimney flues shall be provided with a cleanout opening having a minimum height of 6 inches mm.

  • 2015 International Residential Code
  • 2018 International Mechanical Code
  • Post navigation

The upper edge of the opening shall be located not less than 6 inches mm below the lowest chimney inlet opening. The cleanout shall be provided with a tight-fitting, noncombustible cover. Cleanouts shall not be required for chimney flues serving masonry fireplaces, if such flues are provided with access through the fireplace opening. Appliance connections to a chimney or vent equipped with a power exhauster shall be made on the inlet side of the exhauster.

Masonry chimneys shall be lined. Flue lining systems for use with residential-type and low-heat appliances shall be limited to the following: Clay flue lining shall be installed in accordance with the International Building Code. Listed and labeled chimney lining systems complying with UL